logo
お買い得  オンライン

製品の詳細

ホーム > 製品 >
復元水再利用設備
>
Ultrafiltration Equipment for Electrophoretic Coating Plants with 10t/h Capacity and 55-65% Recovery Rate for Reclaimed Water Reuse

Ultrafiltration Equipment for Electrophoretic Coating Plants with 10t/h Capacity and 55-65% Recovery Rate for Reclaimed Water Reuse

ブランド名: Hongshun
モデル番号: HS-10t/D
MOQ: 1セット
価格: $5,000 to $15,000
梱包の詳細:
支払い条件: LC、T/T
詳細情報
起源の場所:
ドンググアン
証明:
CCC/CE
アプリケーションフィールド:
電気泳動コーティング 工場
生産の水質:
導電性は10μS/cm以下またはそれと同等である. (オンライン機器によるモニタリング,温度25°C)
容量:
10t/h
% 回復:
55~65%
制御方法:
PLC+HIM自動制御
供給の能力:
5セット/月
ハイライト:

Conductivity ≤10μS/cm Ultrafiltration Equipment

,

10t/h Capacity Reclaimed Water Reuse System

,

55-65% Recovery Rate Electrophoretic Coating Water Treatment

製品説明
Ultrafiltration Equipment For Reclaimed Water Reuse In Electrophoretic Coating Plants
Product Description
The ultrafiltration equipment for reclaimed water reuse in electrophoretic coating plants is an essential component in electrophoretic lines, providing multiple critical functions:
  • Recovers electrophoretic paint wastewater from workpiece surfaces, preventing environmental pollution from paint-containing discharge
  • Enables reuse of recycled electrophoretic paint, reducing paint purchase costs by approximately 30%
  • Produces ultrafiltration water for workpiece rinsing, creating a closed-loop circulating water system
  • Removes production-introduced ions from the electrophoretic paint tank through controlled ultrafiltrate discharge, stabilizing the paint solution
The equipment features 1-10 membrane systems with a permeation rate of 60-500 liters and paint feed rate of 1-10m³/h. The complete system includes ultrafiltration raw material pumps, bag filters, specialized ultrafiltration membranes, and frames, with customizable configurations to meet specific requirements.
Design Specifications
Order No. Name Content
1 Device Name 10t/D reclaimed water equipment (1 set)
2 Production Water Quality Conductivity ≤10μS/cm (monitored by online instrument at 25℃)
3 Raw Water Quality Conductivity ≤400μS/cm, flow rate 2t/h
4 Capacity 1t/h at 25℃
5 Recovery Percentage Primary reverse osmosis: 55-65%
6 Technology Pre-treatment sand filter, carbon filter, UF filtration, precision filter, RO reverse osmosis
7 Sterilization Method Sand carbon automatic backwashing, ultraviolet sterilization
8 Control Method PLC+HIM automatic control
9 Equipment Scope From raw water tank inlet to RO outlet (excluding terminal water supply pipe)
Facility Requirements
Order No. Name Content
1 Water Source Reclaimed water (2t/h, 0.2-0.3MPa pressure, φ25 pipe diameter) connected to raw water tank
2 Power Source 4kW normal operating power, 380V/50Hz three-phase five-wire connection
3 Collection Pool Customer-built
6 Drainage 200mm wide × 300mm deep drainage ditch (client responsibility)
7 Installation Space 10m² minimum with proper load-bearing capacity and access
Process Diagram
Ultrafiltration Equipment for Electrophoretic Coating Plants with 10t/h Capacity and 55-65% Recovery Rate for Reclaimed Water Reuse 0