Ultrasonic Vacuum Hydrocarbon Cleaning System for Semiconductor & LCD Substrates
Overview Of Ultrasonic Vacuum Hydrocarbon Cleaning System:
Maintenance & After-Sales Support for Ultrasonic Vacuum Hydrocarbon Cleaning System:
We provide comprehensive maintenance and after-sales support for the HS-6684MFG, ensuring long-term reliable operation. The machine comes with a 1-year warranty (starting from final acceptance), covering free repairs and part replacements for faults caused by normal use. Consumables like filter cartridges, sealing,and heaters are excluded but readily available for purchase.
Routine maintenance is straightforward. The circulation filters (10μ/5μ/20μ/50μ) need monthly replacement (≈15 pieces/month) to maintain filtration efficiency. The heat transfer oil in steam generation and distillation units should be changed every 2500 working hours, while vacuum pump lubricating oil requires checking and topping up every 200 hours. The machine’s accessible design—with a 1-meter maintenance clearance requirement—allows technicians to easily access components like pumps, ultrasonic generators, and electrical cabinets.
After-sales response is prompt: upon receiving a fault notification, the company provides a reply within 4 hours. General faults are resolved within 24 hours, complex issues within 48 hours, and major problems are addressed through mutual negotiation. Additionally, free on-site training (≥24 hours) is offered for 2+ operators, covering mechanical/electrical maintenance, operation, programming, and troubleshooting. Two sets of Chinese operation manuals are provided, with English versions available upon request. For customers needing extended support, paid maintenance contracts (e.g., annual inspections) are also offered.
Consumption of Vacuum Hydrocarbon Cleaner Machine for reference:
order number |
name |
wastage |
remarks |
1 |
hydrocarbons |
Add as required |
It depends on the amount of cleaning |
2 |
Filter cotton core |
About 12 per month |
Replace as required |
3 |
Heat medium oil |
100L/2500 hours |
Replace every 2500 hours of work |
4 |
Vacuum pump lubricating oil |
0.2L/200 hours |
Check and add every 200 hours of work |
5 |
power consumption |
About 30kw/hour |
average value |
6 |
compressed air |
400 NL/min |
Drive use (cylinder, pneumatic valve) |
Our typical customers: