Medium-temperature Sealant for Anodic Oxide Films with pH 5.5 and 10 Kg/Box Packaging for 3-4m²/g Coverage

10 коробок
MOQ
$10-$15/Box
цена
Medium-temperature Sealant for Anodic Oxide Films with pH 5.5 and 10 Kg/Box Packaging for 3-4m²/g Coverage
Характеристики Галерея Характер продукции Поговорите сейчас
Характеристики
Характеристики
Использовать: Анодные оксидные пленки алюминия и алюминиевых сплавов
Появление: Светло-зеленый порошок
Упаковка: 10 кг/коробка
Выделить:

pH 5.5 Medium-temperature Sealant

,

10 Kg/Box Anodic Oxide Film Sealant

,

3-4m²/g Aluminum Alloy Sealant

Основная информация
Место происхождения: Дунгуан
Фирменное наименование: Hongshun
Сертификация: ISO9001
Номер модели: HS-Seal102
Оплата и доставка Условия
Упаковывая детали: коробка
Время доставки: 10 дней
Условия оплаты: Л/К, Т/Т
Поставка способности: 500 ведер/месяц
Характер продукции
Medium-temperature Sealants For Anodic Oxide Films Of Aluminum And Aluminum Alloys
Medium-temperature sealants for anodic oxide films of aluminum and aluminum alloys provide excellent sealing performance with a smooth, fine finish. These sealants effectively prevent common issues such as dye fading, powder film formation, and gray mist appearance.
Key Features
  • Superior sealing quality for demanding applications
  • Ideal for electronic product casings and high-end cosmetic packaging
  • Excellent cost-performance ratio compared to market alternatives
  • Light green powder formulation
Application Method
When preparing the bath solution, maintain pH at 5.5. Note that pH levels may fluctuate with use due to water, acid, and base introduction.
  • Use acid-resistant, high-temperature filters for solution filtration
  • Adjust pH with dilute acetic acid (to lower) or NaOH (to raise)
  • Product specific gravity varies by processing conditions (approximately 3-4m²/g)
Analytical Procedure
  1. Combine 10ml sealing solution with 100ml pure water
  2. Add 10ml 6N-ammonia water and 2-3 drops triethanolamine
  3. Mix in 0.2g MX indicator (solution turns orange)
  4. Titrate with 0.01M-EDTA standard solution until purple-red endpoint (A ml)
Safety & Handling
  • Review product manual and MSDS thoroughly before use
  • Store away from heat sources in well-ventilated areas
  • Wear protective equipment (gloves, goggles, mask) during handling
  • In case of eye contact, rinse immediately with water for 15 minutes and seek medical attention
  • Maintain sealed storage and avoid prolonged exposure after opening